| Response time: |
5ms max |
| Operating
temperature: |
0° to +50°C |
| Enclosure rating: |
IP40 |
| Enclosure: |
70mm DIN rail mounting -
(HxWxD) 90x70x60mm |
| Power supply
requirements: |
22-28V DC ripple <10%
diode protected |
| Current consumption: |
150mA |
| Status indicators: |
LEDs:
Power RED= ON
Inputs YELLOW = ON
Outputs GREEN = ON |
| Ladder Logic rungs: |
36 |
| Timers: |
8 |
| Fault Disparity: |
Checking on outputs |
| Classification: |
BS EN 954-1 Category 4
(Programming dependent) |
|
|
 |
|
| Response time: |
5ms max |
| Operating
temperature: |
0° to +50°C |
| Enclosure rating: |
IP40 |
| Enclosure: |
70mm DIN rail mounting -
(HxWxD) 90x160x60mm |
| Power supply
requirements: |
22-28V DC ripple <10%
diode protected |
| Current consumption: |
150mA |
| Status indicators: |
LEDs:
Power RED= ON
Inputs YELLOW = ON
Outputs GREEN = ON |
| Ladder Logic rungs: |
120 |
| Timers: |
32 |
| Counters: |
4 |
| Speed controllers: |
2 |
| Annunciator: |
1 |
| Fault Disparity: |
User definable anywhere in
the logic circuit |
| Classification: |
BS EN 954-1 Category 4
(Programming dependent) |
| Inputs: |
- 18 Dual electronic safety inputs
- Electronic sink 1mABS EN 954-1 Category 4 (Programming dependent)
|
| Outputs: |
- 6 Dual electronic safety outputs
- Current outputs rated at 0.5A one of which can be split for current monitored mute lamp
output and auxiliary
- 2 Dual electronic safety outputs
- Current outputs rated at 60mA
|
|
|
Product Conformity.
Smartscan Multifunction Safety Units conform to the following Directives: 89/336/EEC,
92/31/EEC, 98/37/EC, 73/23/EEC uses the following Standards EN292-1, EN292-2, EN60204-1,
EN954-1. CE Marking has been applied to this safety component under the terms of
Directives 89/336/EEC, 92/31/EEC and 93/68/EEC. |
|