Machine safety systems and products, including safety light curtains, safety gate interlocks, safety relays and safety PLCs. Click here to return home at any time.
New Product - T4 Series Safety Light Curtain

- Type 4, Category 4, SIL 3 rating for high risk applications
- Robust (twin chamber) housing and IP65 rating
- 14, 30 and 40mm ODC plus Perimeter guarding
Peace of Mind - Smartscan Maintenance Package

- Help reduce costly unplanned downtime through scheduled quality maintenance.
- Continued compliance with legislation and machine safety standards
Smartscan Ltd, for machine safety systems and products, including safety light curtains, safety gate interlocks, safety relays and safety PLCs.
boxtop_l.gif (124 bytes) boxtop_r.gif (124 bytes)
•  Overview
•  Model Range
•  Specifications
•  Accessories
•  Technical Support
•  Documentation

Integron.

Integron.

Products: Safety PLCs - Model Range

The Integron safety PLCs currently come in 2 safety I/O options, 7 dual electronic safety inputs and 4 dual electronic safety outputs or 18 dual electronic safety inputs and 8 dual electronic safety outputs. Please scroll down the page or use the following links to learn more.

boxtop_l.gif (124 bytes) boxtop_r.gif (124 bytes)
Windows® based software used for programming the memory modules for the Integron range. Using industry standard ladder logic, the software is compatible with all three versions of the Integron.

Requirements:

  • Microsoft Windows based PC running Windows 98 – XP
  • Minimum 100 MHz processor
  • Minimum 64mb RAM
  • CDROM drive
  • 3.5” Floppy disc drive
  • Serial port
px.gif (818 bytes)
boxtop_l.gif (124 bytes) boxtop_r.gif (124 bytes)
Required for ‘blowing’ the Smartgram developed program onto the memory modules. The unit is only required by those who develop the Integron programs or need to burn them onto memory modules.
px.gif (818 bytes)
boxtop_l.gif (124 bytes) boxtop_r.gif (124 bytes)
Inputs: 7 Dual inputs
Outputs: 3 Dual safety high current outputs 0.5A
- 1 Dual safety low current output 60mA
Fault disparity: - Checking on outputs
Logic rungs: 36 -
Timers: 8 -
px.gif (818 bytes)
boxtop_l.gif (124 bytes) boxtop_r.gif (124 bytes)
Inputs: 18 Dual inputs
Outputs: 6 Safety high current outputs 0.5A one of which can be split for current monitored mute lamp output and auxiliary.
- 2 Dual safety electronic outputs 60mA
Fault disparity: - User definable anywhere in the logic circuit
Logic rungs: 120 -
Timers: 32 -
Counters: 4 -
Speed controllers: 2 -
Annunciator: 1 -